100 pT/cm single-point MEMS magnetic gradiometer from a commercial accelerometer

Date
2020
Authors
Javor, Josh
Stange, Alexander
Pollock, Corey
Fuhr, Nicholas
Bishop, David J.
Version
Published version
OA Version
Citation
J. Javor, A. Stange, C. Pollock, N. Fuhr, D.J. Bishop. 2020. "100 pT/cm single-point MEMS magnetic gradiometer from a commercial accelerometer." Microsystems & Nanoengineering, Volume 6, Issue 1, pp.71-. https://doi.org/10.1038/s41378-020-0173-z
Abstract
Magnetic sensing is present in our everyday interactions with consumer electronics and demonstrates the potential for the measurement of extremely weak biomagnetic fields, such as those of the heart and brain. In this work, we leverage the many benefits of microelectromechanical system (MEMS) devices to fabricate a small, low-power, and inexpensive sensor whose resolution is in the range of biomagnetic fields. At present, biomagnetic fields are measured only by expensive mechanisms such as optical pumping and superconducting quantum interference devices (SQUIDs), suggesting a large opportunity for MEMS technology in this work. The prototype fabrication is achieved by assembling micro-objects, including a permanent micromagnet, onto a postrelease commercial MEMS accelerometer using a pick-and-place technique. With this system, we demonstrate a room-temperature MEMS magnetic gradiometer. In air, the sensor's response is linear, with a resolution of 1.1 nT cm-1, spans over 3 decades of dynamic range to 4.6 µT cm-1, and is capable of off-resonance measurements at low frequencies. In a 1 mTorr vacuum with 20 dB magnetic shielding, the sensor achieves a 100 pT cm-1 resolution at resonance. This resolution represents a 30-fold improvement compared with that of MEMS magnetometer technology and a 1000-fold improvement compared with that of MEMS gradiometer technology. The sensor is capable of a small spatial resolution with a magnetic sensing element of 0.25 mm along its sensitive axis, a >4-fold improvement compared with that of MEMS gradiometer technology. The calculated noise floor of this platform is 110 fT cm-1 Hz-1/2, and thus, these devices hold promise for both magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
Description
License
© The Author(s) 2020. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.